VETIVD™ Trusted partner for the global veterinary IVD community Simple
Sensitive · Fast · Precision
  • cTT4 Canine Rapid Tests(FIA) | Canine Total Thyroxine(cTT4)Rapid Quantitative Test | VETIVD™ cTT4 12 minutes to detect results
  • cTT4 Canine Rapid Tests(FIA) | Canine Total Thyroxine(cTT4)Rapid Quantitative Test | VETIVD™ cTT4 12 minutes to detect results
  • cTT4 Canine Rapid Tests(FIA) | Canine Total Thyroxine(cTT4)Rapid Quantitative Test | VETIVD™ cTT4 12 minutes to detect results
  • cTT4 Canine Rapid Tests(FIA) | Canine Total Thyroxine(cTT4)Rapid Quantitative Test | VETIVD™ cTT4 12 minutes to detect results
  • cTT4 Canine Rapid Tests(FIA) | Canine Total Thyroxine(cTT4)Rapid Quantitative Test | VETIVD™ cTT4 12 minutes to detect results
  • cTT4 Canine Rapid Tests(FIA) | Canine Total Thyroxine(cTT4)Rapid Quantitative Test | VETIVD™ cTT4 12 minutes to detect results
  • cTT4 Canine Rapid Tests(FIA) | Canine Total Thyroxine(cTT4)Rapid Quantitative Test | VETIVD™ cTT4 12 minutes to detect results
  • cTT4 Canine Rapid Tests(FIA) | Canine Total Thyroxine(cTT4)Rapid Quantitative Test | VETIVD™ cTT4 12 minutes to detect results

cTT4 Canine Rapid Tests(FIA) | Canine Total Thyroxine(cTT4)Rapid Quantitative Test | VETIVD™ cTT4 12 minutes to detect results

The cTT4 test is a fluorescence immunoassay used along with Immunofluorescence Analyzer for quantitative determination of total thyroxine concentration in canine serum or plasma specimen. The test is used to assist in the evaluation of thyroid function.

cTT4 Reference range:

Result(Tu/ml)                       Suggestion

        ≤ 15                                    low

     15 ~ 60                                 normal

      > 100                                   high

Each laboratory should establish a reference range that is representative of the population to be evaluated.

  • cTT4 Canine Rapid Tests(FIA) | Canine Total Thyroxine(cTT4)Rapid Quantitative Test | VETIVD™ cTT4 12 minutes to detect results
  • cTT4 Canine Rapid Tests(FIA) | Canine Total Thyroxine(cTT4)Rapid Quantitative Test | VETIVD™ cTT4 12 minutes to detect results
  • cTT4 Canine Rapid Tests(FIA) | Canine Total Thyroxine(cTT4)Rapid Quantitative Test | VETIVD™ cTT4 12 minutes to detect results
  • cTT4 Canine Rapid Tests(FIA) | Canine Total Thyroxine(cTT4)Rapid Quantitative Test | VETIVD™ cTT4 12 minutes to detect results
PRODUT DETAILS

Advanced Detection Technology

VETIVD™  cTT4  Rapid Quantitative Test utilizes the cutting-edge third generation
time-resolved immunofluorescence chromatography technology. It employs rare earth element
europium (Eu3+) coated nano-fluorescent microspheres as a distinctive marker, and swiftly
achieves quantitative analysis by analyzing the fluorescence intensity of both the detection zone
and quality control zone.


Third generation time-resolved immunofluorescence chromatography
(double antigen sandwich method)


Rigorous clinical trials
At VETIVD™, we conduct over 500 clinical trials for each product in collaboration with veterinary
university laboratories to ensure that the effectiveness of each product meets thebest standards.

VETIVD™  cTT4  Total clinical trial sample: 1181
Positive sample: 466       Negative sample: 715

Specificity>99.84%    Sensitivity>94.76%


Innovative technical support
The VETIVD™ Rapid Quantitative Test utilizes an innovative QR code design in conjunction with
an intelligent identification system to automatically discern sample types, information, and
production batches.


User feedback data display
95% of veterinarians believe
Error rate reduced to 0%

Smart and convenient

Excellent  stability
VETIVD™ employs novel stabilizers, protectants, and cutting-edge packaging technology to
ensure consistent reagent performance across diverse environments.

Tested for long-term storage and transportation
Storage in 4~30℃ environment

 Performance change rate within 2 years is less than 0.03%


Simple detection process
The testing process of VETIVD™ Rapid Quantitative Test has been meticulously optimized,
resulting in a streamlined clinical testing procedure consisting of only 7 steps. This ensures that
users are provided with a diagnostic solution that is both convenient and highly efficient.



Strict quality control
The VETIVD™ brand boasts a state-of-the-art GMP production workshop spanning 5,000 square
meters. From meticulous R&D to precise manufacturing processes, we meticulously select
premium-grade raw materials and enforce stringent quality control measures at every stage,
ensuring unparalleled excellence in our products.



Performance comparison of 4 technology platforms

Methodology
VETIVD™ Time-resolved immunofluorescence chromatography
Conventional immunofluorescence chromatography
Colloidal gold immunochromatography
Enzyme-linked immunity
Marker Nano europium fluorescent microspheres Fluorescein Colloidal gold Enzyme
Qualitative or quantitative Full quantitation Quantify Qualitative semi-quantitative
Kit components 1-2 kinds 1-2 kinds 1-2 kinds 7 kinds
Steps Step 1-2 Step 1-2 Step 1-2 Step 10-15
Sensitivity higher lower low high
Detection time 3-10 minutes 10-15 minutes 15 minutes 120 minutes
Specificity Excellent Normal Normal Normal
Storage method 4-30℃ 2-8℃ 4-30℃ 2-8℃
Epidemic monitoring

X